Here you will find technical information
regarding certain chimney pots and accessories not shown on product price pages.
ULTIMATE FLUE
OUTLET
ANTI-DOWNDRAUGHT
COWL
MT01
MT09
Following wind testing
by British Gas Research the Ultimate Flue Outlet is the first Chimney
Cowl to be certified for use on 200mm diameter flue sizes according to
BS715:1993.
* Certified to BS715:1993
* Suitable for All Gas
Appliances to BS5871:1991 Parts 1,2 & 3, in particular DFE and ILFE
fires.
* Excellent performance
on Oil Appliances.
* May also be used with
Solid Fuel Open Fires and Appliances. (Please note: factory fitted
bird guard for gas use must be removed before installation -
single screw fixing).
* Adjusts to fit 150mm to
250mm diameter pots or terminals.
* Offers bird and rain
protection.
* Quality Aluminium Alloy
with powder coated paint finish in terracotta as standard for longer
life, other colours available on request.
GC2 & GC3
APPLICATION
GC2
GC3
GC2
Bishop
All GC2 terminals have nominal 130mm
diameter internal dimensions at the terminal inlet and must only be
connected to the following types of natural draught domestic gas
appliances.
a. Central heating boilers which have
a flue outlet spigots not greater than 125mm diameter. Combination gas
fire/back boiler units with similarly sized flue outlets are also
suitable.
b. Gas fires which comply with BS
5258: Part 5 (1975). Older fires which complied with BS 1250 may also
be suitable.
The GC3 terminal is a larger version
of the GC2 insert. It has a nominal 150mm diameter dimension on its
inlet and is only suitable for use with natural draught boilers or
combination units with flue spigots not exceeding 150mm diameter, and
gas fires as described in b. above.
Important - The appliance
manufacturers' installation instructions must be followed at all times.
GC2 and GC3 terminals are not suitable for use with 'decorative fuel
effect' gas appliances installed to BS5871: Part 3.
The Bishop GC2 if used with a metal
flue liner, the base should be fixed in the same as the standard the
standard GC2. It is recommended that the crown and GC2 are fixed
together on the ground with two 300mm lengths of 15swg. copper wire.
The inside of the crown should be sealed with mortar checking that the
drainage holes are clear.
When the base has been flaunched on
the stack and the terminal placed dry to determine the most suitable
seating position, apply a bead of mortar to the top ring and lugs of the
base.
GC5 & STANGAS
TERMINALS
GC5
Stangas Insert
The GC5 and Stangas Inserts are
designed to provide an effective gas flue termination to existing flues
whilst keeping a low profile. The crowned GC5 Insert has the appearance
of a traditional chimney pot, making it particularly suitable for
conversion work on older properties.
All terminals are tested and approved
by British Gas for use with the following types of natural draught
domestic gas appliances:
a. Central heating boilers which have
a flue outlet spigots not greater than 125mm diameter. Combination gas
fire/back boiler units with similar sized flue outlets are also
suitable.
b. Gas fire which comply with BS
5258: Part 5 (1975). Older fires which complied with BS 1250 may also
be suitable.
GC5 and Stangas terminals are
available in three colours - Red Terracotta, Buff Fireclay, and Blue
Black.
Important - The appliance
manufacturers installation instructions must be followed at all times.
GC5 and Stangas Terminals are NOT
suitable for use with 'decorative fuel effect' gas appliances installed
to BS 5871: Part 3. INSET LIVE FUEL
FIRES AND DECORATIVE FUEL EFFECT GAS FIRES
DFE
Pot
DFE
Insert
GC9
Terminal
These three patterns of chimney
pots are manufactured to BS 5871 - Specification for installation of Gas Fires,
Convector Heaters, Fireback Boilers and Decorative Fuel Effect Gas Appliances,
Part 3 Decorative Fuel Effect Gas Appliances of Heat Input not Exceeding 15KW. |